Commit 916030db authored by Alexandre Belloni's avatar Alexandre Belloni Committed by Thierry Reding

pwm: atmel: correct CDTY calculation

From the datasheet, the actual duty cycle is:

	(period - (1 / clk) * CDTY) / period

This actually correct the polarity of the PWM and solves the issue that
pwm-leds exhibits: when setting a duty cycle of 0 and then disabling a
channel, the level was wrong (1 when the polarity was normal and 0 when
the polarity was inversed).
Signed-off-by: default avatarAlexandre Belloni <alexandre.belloni@free-electrons.com>
Acked-by: default avatarNicolas Ferre <nicolas.ferre@atmel.com>
Signed-off-by: default avatarThierry Reding <thierry.reding@gmail.com>
parent 8db9e29f
......@@ -133,7 +133,7 @@ static int atmel_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm,
prd = div;
div *= duty_ns;
do_div(div, period_ns);
dty = div;
dty = prd - div;
ret = clk_enable(atmel_pwm->clk);
if (ret) {
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment