iio: adc: ina2xx: Actually align the loop with the conversion ready flag
Currently, the registers are read out once per conversion interval. If the reading is delayed as the conversion has not yet finished, this extra time is treated as being part of the readout, although it should delay the start of the poll interval. This results in the interval starting slightly earlier in each iteration, until all time between reads is spent polling the status registers instead of sleeping. To fix this, the delay has to account for the state of the conversion ready flag. Whenever the conversion is already finished, schedule the next read on the regular interval, otherwise schedule it one interval after the flag bit has been set. Split the work function in two functions, one for the status poll and one for reading the values, to be able to note down the time when the flag bit is raised. Signed-off-by: Stefan Brüns <stefan.bruens@rwth-aachen.de> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>