Commit 9da82fb7 authored by Markus Theil's avatar Markus Theil Committed by Felix Fietkau

mt76: allow more channels, allowed in ETSI domain

While looking at the ETSI regulatory domain definitions
and a patch, which allows more channels for ath10k, I also
checked the channels allowed for mt76.

ETSI regulations would possibly allow to add channels 32, 68,
96, 144, 169 and 173. IEEE 802.11-2016 defines no operating class
for channels 32, 68 and 96. This leaves us channels 144, 169 and 173,
which are included in this patch.

I tested 169 and 173 with a mt76 based USB dongle (AVM AC 860) and they
worked fine. If I saw that right, these channels are also covered by
register definitions inside the driver.

Channel 144 should also work, but gets disabled by the kernel as of now.
Signed-off-by: default avatarMarkus Theil <markus.theil@tu-ilmenau.de>
Signed-off-by: default avatarFelix Fietkau <nbd@nbd.name>
parent 642023d0
......@@ -58,12 +58,15 @@ static const struct ieee80211_channel mt76_channels_5ghz[] = {
CHAN5G(132, 5660),
CHAN5G(136, 5680),
CHAN5G(140, 5700),
CHAN5G(144, 5720),
CHAN5G(149, 5745),
CHAN5G(153, 5765),
CHAN5G(157, 5785),
CHAN5G(161, 5805),
CHAN5G(165, 5825),
CHAN5G(169, 5845),
CHAN5G(173, 5865),
};
static const struct ieee80211_tpt_blink mt76_tpt_blink[] = {
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment