pwm: crc: Fix off-by-one error in the clock-divider calculations
The CRC PWM controller has a clock-divider which divides the clock with a value between 1-128. But as can seen from the PWM_DIV_CLK_xxx defines, this range maps to a register value of 0-127. So after calculating the clock-divider we must subtract 1 to get the register value, unless the requested frequency was so high that the calculation has already resulted in a (rounded) divider value of 0. Note that before this fix, setting a period of PWM_MAX_PERIOD_NS which corresponds to the max. divider value of 128 could have resulted in a bug where the code would use 128 as divider-register value which would have resulted in an actual divider value of 0 (and the enable bit being set). A rounding error stopped this bug from actually happen. This same rounding error means that after the subtraction of 1 it is impossible to set the divider to 128. Also bump PWM_MAX_PERIOD_NS by 1 ns to allow setting a divider of 128 (register-value 127). Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Acked-by: Thierry Reding <thierry.reding@gmail.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Link: https://patchwork.freedesktop.org/patch/msgid/20200903112337.4113-10-hdegoede@redhat.com