MIPS: io: Add barrier after register read in readX()
While a barrier is present in the writeX() functions before the register write, a similar barrier is missing in the readX() functions after the register read. This could allow memory accesses following readX() to observe stale data. Signed-off-by: Sinan Kaya <okaya@codeaurora.org> Reported-by: Arnd Bergmann <arnd@arndb.de> Cc: Ralf Baechle <ralf@linux-mips.org> Cc: Paul Burton <paul.burton@mips.com> Cc: linux-mips@linux-mips.org Patchwork: https://patchwork.linux-mips.org/patch/19069/ [jhogan@kernel.org: Tidy commit message] Signed-off-by: James Hogan <jhogan@kernel.org>