Commit b3bf0e90 authored by Ruslan Ruslichenko's avatar Ruslan Ruslichenko Committed by Greg Kroah-Hartman

staging: omap-thermal: Add print when TSHUT temperature reached

To indicate that board was shut down due to TSHUT temperature reached
it is good to print some information message before shutting down.
Signed-off-by: default avatarRuslan Ruslichenko <x0191366@ti.com>
Signed-off-by: default avatarEduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 72c1c06d
......@@ -133,6 +133,9 @@ static irqreturn_t talert_irq_handler(int irq, void *data)
/* This is the Tshut handler. Call it only if HAS(TSHUT) is set */
static irqreturn_t omap_bandgap_tshut_irq_handler(int irq, void *data)
{
pr_emerg("%s: TSHUT temperature reached. Needs shut down...\n",
__func__);
orderly_poweroff(true);
return IRQ_HANDLED;
......
Markdown is supported