Commit b652bd83 authored by Ian Abbott's avatar Ian Abbott Committed by Greg Kroah-Hartman

staging: comedi: addi_apci_2032: make insn_bits read live data

The `insn_bits` handler for the special digital input subdevice used for
interrupts currently uses `s->state` for the data value, which is set to
the value of the APCI2032_INT_STATUS_REG register when a valid interrupt
occurs.  Just read the live register contents in the `insn_bits` handler
instead of relying on the interrupt service routine to read it for us.

The register contains a couple of hardware error status bits.  They
might also be valid even when the corresponding bits have not been
enabled in the APCI_INT_CTRL_REG register in which case this would be
useful for checking for hardware errors without using interrupts, but
this needs to be checked.
Signed-off-by: default avatarIan Abbott <abbotti@mev.co.uk>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@linuxfoundation.org>
parent 6bf9a3ba
......@@ -159,7 +159,7 @@ static int apci2032_int_insn_bits(struct comedi_device *dev,
struct comedi_insn *insn,
unsigned int *data)
{
data[1] = s->state;
data[1] = inl(dev->iobase + APCI2032_INT_STATUS_REG) & 3;
return insn->n;
}
......@@ -245,10 +245,10 @@ static irqreturn_t apci2032_interrupt(int irq, void *d)
if (!val)
return IRQ_NONE;
s->state = inl(dev->iobase + APCI2032_INT_STATUS_REG);
outl(0x0, dev->iobase + APCI2032_INT_CTRL_REG);
val = inl(dev->iobase + APCI2032_INT_STATUS_REG) & 3;
outl(0x00, dev->iobase + APCI2032_INT_CTRL_REG);
if (comedi_buf_put(s->async, s->state))
if (comedi_buf_put(s->async, val))
s->async->events |= COMEDI_CB_BLOCK | COMEDI_CB_EOS;
else
s->async->events |= COMEDI_CB_OVERFLOW;
......