drm/bridge: Clear the DP_AUX_I2C_MOT bit passed in aux read command.
If the previous transfer didn't end with a command without DP_AUX_I2C_MOT, the next read trasnfer will miss the first byte. But if the command in previous transfer is requested with length 0, it's a no-op to anx7625 since it can't process this command. anx7625 requires the last command to be read command with length > 0. It's observed that if we clear the DP_AUX_I2C_MOT in read transfer, we can still get correct data. Clear the read commands with DP_AUX_I2C_MOT bit to fix this issue. Fixes: adca62ec ("drm/bridge: anx7625: Support reading edid through aux channel") Signed-off-by: Hsin-Yi Wang <hsinyi@chromium.org> Reviewed-by: Xin Ji <xji@analogixsemi.com> Signed-off-by: Robert Foss <robert.foss@linaro.org> Link: https://patchwork.freedesktop.org/patch/msgid/20220217082224.1823916-1-hsinyi@chromium.org