[BNX2]: Fix ASYM PAUSE advertisement for remote PHY.
We were checking for the ASYM_PAUSE bit for 1000Base-X twice instead checking for both the 1000Base-X bit and the 10/100/1000Base-T bit. The purpose of the logic is to tell the firmware that ASYM_PAUSE is set on either the Serdes or Copper interface. Problem was discovered by Roel Kluin <12o3l@tiscali.nl> Signed-off-by: Michael Chan <mchan@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>