Commit c6463c65 authored by Damien Le Moal's avatar Damien Le Moal Committed by Jens Axboe

sd_zbc: Force use of READ16/WRITE16

Normally, sd_read_capacity sets sdp->use_16_for_rw to 1 based on the
disk capacity so that READ16/WRITE16 are used for large drives.
However, for a zoned disk with RC_BASIS set to 0, the capacity reported
through READ_CAPACITY may be very small, leading to use_16_for_rw not being
set and READ10/WRITE10 commands being used, even after the actual zoned disk
capacity is corrected in sd_zbc_read_zones. This causes LBA offset overflow for
accesses beyond 2TB.

As the ZBC standard makes it mandatory for ZBC drives to support
the READ16/WRITE16 commands anyway, make sure that use_16_for_rw is set.
Signed-off-by: default avatarDamien Le Moal <damien.lemoal@wdc.com>
eviewed-by: default avatarChristoph Hellwig <hch@lst.de>
Signed-off-by: default avatarJens Axboe <axboe@fb.com>
parent dbb3ab03
......@@ -612,6 +612,10 @@ int sd_zbc_read_zones(struct scsi_disk *sdkp,
if (ret)
goto err;
/* READ16/WRITE16 is mandatory for ZBC disks */
sdkp->device->use_16_for_rw = 1;
sdkp->device->use_10_for_rw = 0;
return 0;
err:
......