Commit d2e61512 authored by Kumar Gala's avatar Kumar Gala Committed by Paul Mackerras

[PATCH] powerpc: Make sure we have an RTC before trying to adjust it

Its valid for ppc_md.set_rtc_time to be NULL.  We need to check
that its non-NULL before trying to update the RTC.
Signed-off-by: default avatarKumar K. Gala <kumar.gala@freescale.com>
Signed-off-by: default avatarPaul Mackerras <paulus@samba.org>
parent 34060104
......@@ -154,7 +154,7 @@ static __inline__ void timer_check_rtc(void)
* We should have an rtc call that only sets the minutes and
* seconds like on Intel to avoid problems with non UTC clocks.
*/
if (ntp_synced() &&
if (ppc_md.set_rtc_time && ntp_synced() &&
xtime.tv_sec - last_rtc_update >= 659 &&
abs((xtime.tv_nsec/1000) - (1000000-1000000/HZ)) < 500000/HZ &&
jiffies - wall_jiffies == 1) {
......