iio: temperature: mcp9600: add threshold events support
The device has four programmable temperature alert outputs which can be used to monitor hot or cold-junction temperatures and detect falling and rising temperatures. It supports up to 255 degree celsius programmable hysteresis. Each alert can be individually configured by setting following options in the associated alert configuration register: - monitor hot or cold junction temperature - monitor rising or falling temperature - set comparator or interrupt mode - set output polarity - enable alert This patch binds alert outputs to iio events: - alert1: hot junction, rising temperature - alert2: hot junction, falling temperature - alert3: cold junction, rising temperature - alert4: cold junction, falling temperature All outputs are set in comparator mode and polarity depends on interrupt configuration. Signed-off-by: Dimitri Fedrau <dima.fedrau@gmail.com> Link: https://lore.kernel.org/r/20240604133639.959682-1-dima.fedrau@gmail.comSigned-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>