pwm: stm32: Improve precision of calculation in .apply()
While mathematically it's ok to calculate the number of cyles for the duty cycle as: duty_cycles = period_cycles * duty_ns / period_ns this doesn't always give the right result when doing integer math. This is best demonstrated using an example: With the input clock running at 208877930 Hz a request for duty_cycle = 383 ns and period = 49996 ns results in period_cycles = clkrate * period_ns / NSEC_PER_SEC = 10443.06098828 Now calculating duty_cycles with the above formula gives: duty_cycles = 10443.06098828 * 383 / 49996 = 80.00024719 However with period_cycle truncated to an integer results in: duty_cycles = 10443 * 383 / 49996 = 79.99977998239859 So while a value of (a little more than) 80 would be the right result, only 79 is used here. The problem here is that 14443 is a rounded result that should better not be used to do further math. So to fix that use the exact formular similar to how period_cycles is calculated. Link: https://lore.kernel.org/r/7628ecd8a7538aa5a7397f0fc4199a077168e8a6.1710711976.git.u.kleine-koenig@pengutronix.deSigned-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>