Commit e6a0b495 authored by Martin Hundebøll's avatar Martin Hundebøll Committed by Antonio Quartulli

batman-adv: Fix endianness errors for network coding

Add a htonl() in network_coding.c when reading the sequence number
from received ogm_packet, to avoid wrong byte ordering when comparing
with a host value. This bug was introduced in
3ed7ada3f0bbcd058567bc0a8f9729a73eba7db6 ("batman-adv: network coding -
detect coding nodes and remove these after timeout").

Change the type of coded_packet->coded_len from uint16 to __be16 to
avoid wrong assumptions about endianness in later uses. Introduced in
c3289f3650d34b60296000a629c99f2488f7c3dd ("batman-adv: network coding -
code and transmit packets if possible").
Reported-by: default avatarFengguang Wu <fengguang.wu@intel.com>
Signed-off-by: default avatarMartin Hundebøll <martin@hundeboll.net>
Signed-off-by: default avatarMarek Lindner <lindner_marek@yahoo.de>
Signed-off-by: default avatarAntonio Quartulli <ordex@autistici.org>
parent 6bdeaba4
......@@ -654,7 +654,7 @@ static bool batadv_can_nc_with_orig(struct batadv_priv *bat_priv,
struct batadv_orig_node *orig_node,
struct batadv_ogm_packet *ogm_packet)
{
if (orig_node->last_real_seqno != ogm_packet->seqno)
if (orig_node->last_real_seqno != ntohl(ogm_packet->seqno))
return false;
if (orig_node->last_ttl != ogm_packet->header.ttl + 1)
return false;
......
......@@ -308,7 +308,7 @@ struct batadv_coded_packet {
uint8_t second_source[ETH_ALEN];
uint8_t second_orig_dest[ETH_ALEN];
__be32 second_crc;
uint16_t coded_len;
__be16 coded_len;
};
#endif /* _NET_BATMAN_ADV_PACKET_H_ */
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment