[media] cx25840: fix regression in analog support hue/saturation controls
Fix regression in HVR-1800 analog support hue/saturation controls. The changes made for the cx23888 caused regressions in the analog support for cx23885/cx23887 based boards (partly due to changes in the locations of the hue/saturation controls). As a result the wrong registers were being overwritten. Add code to use the correct registers if it's a cx23888 Validated with the following boards: HVR-1800 retail (0070:7801) HVR-1800 OEM (0070:7809) HVR-1850 retail (0070:8541) Thanks to Steven Toth and Hauppauge for loaning me various boards to regression test with. Reported-by: Jonathan <sitten74490@mypacks.net> Thanks-to: Steven Toth <stoth@kernellabs.com> Signed-off-by: Devin Heitmueler <dheitmueller@kernellabs.com> Signed-off-by: Mauro Carvalho Chehab <mchehab@redhat.com>