Commit eb7c00e1 authored by Wolfram Sang's avatar Wolfram Sang Committed by Ulf Hansson

mmc: host: tmio: fill in response from auto cmd12

After we received the dataend interrupt, R1 response register carries
the value from the automatically generated stop command. Report that
info back to the MMC block layer, so we will be notified in case of e.g.
ECC errors which happened during the last transfer.
Reviewed-by: default avatarSimon Horman <horms+renesas@verge.net.au>
Tested-by: default avatarYoshihiro Shimoda <yoshihiro.shimoda.uh@renesas.com>
Signed-off-by: default avatarWolfram Sang <wsa+renesas@sang-engineering.com>
Signed-off-by: default avatarUlf Hansson <ulf.hansson@linaro.org>
parent 022f731e
......@@ -557,6 +557,9 @@ void tmio_mmc_do_data_irq(struct tmio_mmc_host *host)
dev_err(&host->pdev->dev, "unsupported stop: CMD%u,0x%x. We did CMD12,0\n",
stop->opcode, stop->arg);
/* fill in response from auto CMD12 */
stop->resp[0] = sd_ctrl_read16_and_16_as_32(host, CTL_RESPONSE);
sd_ctrl_write16(host, CTL_STOP_INTERNAL_ACTION, 0);
}
......