staging: comedi: usbduxsigma: round down AO scan_begin_arg at step 4.
The return value of the `cmdtest` handler for a subdevice checks the prospective new command in various steps and returns the step number at which any problem was detected, or 0 if no problem was detected. It is allowed to modify the command in various ways at each step. Corrections for out-of-range values are generally made at step 3, and minor adjustments such as rounding are generally made at step 4. The `cmdtest` handler for the AO subdevice (`usbduxsigma_ao_cmdtest()`) currently range checks the timings at step 3. Since the running command will round down the timings, add code to round them down at step 4. Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Reviewed-by: Bernd Porr <mail@berndporr.me.uk> Reviewed-by: H Hartley Sweeten <hsweeten@visionengravers.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>