Commit f3c158ab authored by Sagi Grimberg's avatar Sagi Grimberg Committed by Jiri Slaby

Target/iser: Improve cm events handling

commit 88c4015f upstream.

There are 4 RDMA_CM events that all basically mean that
the user should teardown the IB connection:
- DISCONNECTED
- ADDR_CHANGE
- DEVICE_REMOVAL
- TIMEWAIT_EXIT

Only in DISCONNECTED/ADDR_CHANGE it makes sense to
call rdma_disconnect (send DREQ/DREP to our initiator).
So we keep the same teardown handler for all of them
but only indicate calling rdma_disconnect for the relevant
events.

This patch also removes redundant debug prints for each single
event.

v2 changes:
 - Call isert_disconnected_handler() for DEVICE_REMOVAL (Or + Sag)
Signed-off-by: default avatarSagi Grimberg <sagig@mellanox.com>
Signed-off-by: default avatarNicholas Bellinger <nab@linux-iscsi.org>
Signed-off-by: default avatarJiri Slaby <jslaby@suse.cz>
parent 34992ea5
......@@ -689,8 +689,10 @@ isert_disconnect_work(struct work_struct *work)
return;
}
/* Send DREQ/DREP towards our initiator */
rdma_disconnect(isert_conn->conn_cm_id);
if (isert_conn->disconnect) {
/* Send DREQ/DREP towards our initiator */
rdma_disconnect(isert_conn->conn_cm_id);
}
mutex_unlock(&isert_conn->conn_mutex);
......@@ -700,10 +702,11 @@ isert_disconnect_work(struct work_struct *work)
}
static void
isert_disconnected_handler(struct rdma_cm_id *cma_id)
isert_disconnected_handler(struct rdma_cm_id *cma_id, bool disconnect)
{
struct isert_conn *isert_conn = (struct isert_conn *)cma_id->context;
isert_conn->disconnect = disconnect;
INIT_WORK(&isert_conn->conn_logout_work, isert_disconnect_work);
schedule_work(&isert_conn->conn_logout_work);
}
......@@ -712,29 +715,28 @@ static int
isert_cma_handler(struct rdma_cm_id *cma_id, struct rdma_cm_event *event)
{
int ret = 0;
bool disconnect = false;
pr_debug("isert_cma_handler: event %d status %d conn %p id %p\n",
event->event, event->status, cma_id->context, cma_id);
switch (event->event) {
case RDMA_CM_EVENT_CONNECT_REQUEST:
pr_debug("RDMA_CM_EVENT_CONNECT_REQUEST: >>>>>>>>>>>>>>>\n");
ret = isert_connect_request(cma_id, event);
break;
case RDMA_CM_EVENT_ESTABLISHED:
pr_debug("RDMA_CM_EVENT_ESTABLISHED >>>>>>>>>>>>>>\n");
isert_connected_handler(cma_id);
break;
case RDMA_CM_EVENT_DISCONNECTED:
pr_debug("RDMA_CM_EVENT_DISCONNECTED: >>>>>>>>>>>>>>\n");
isert_disconnected_handler(cma_id);
break;
case RDMA_CM_EVENT_DEVICE_REMOVAL:
case RDMA_CM_EVENT_ADDR_CHANGE:
case RDMA_CM_EVENT_ADDR_CHANGE: /* FALLTHRU */
case RDMA_CM_EVENT_DISCONNECTED: /* FALLTHRU */
case RDMA_CM_EVENT_DEVICE_REMOVAL: /* FALLTHRU */
disconnect = true;
case RDMA_CM_EVENT_TIMEWAIT_EXIT: /* FALLTHRU */
isert_disconnected_handler(cma_id, disconnect);
break;
case RDMA_CM_EVENT_CONNECT_ERROR:
default:
pr_err("Unknown RDMA CMA event: %d\n", event->event);
pr_err("Unhandled RDMA CMA event: %d\n", event->event);
break;
}
......
......@@ -121,6 +121,7 @@ struct isert_conn {
int conn_frwr_pool_size;
/* lock to protect frwr_pool */
spinlock_t conn_lock;
bool disconnect;
};
#define ISERT_MAX_CQ 64
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment