Commit f451655c authored by Hans de Goede's avatar Hans de Goede Committed by Sebastian Reichel

power: supply: axp288_fuel_gauge: Fix full status reporting

Commit 2b5a4b4b ("power: supply: axp288_fuel_gauge: Rework
get_status()"), switched from 0A current detection to using the capacity
register for full detection.

It turns out this fixes full reporting on some devices which keep trickle
charging long after the capacity register reach 100%, but breaks it on
some other devices where the charger stops charging before the capacity
register reaches 100%. This commit fixes this by also checking for
0A current when the reported capacity is above 90%.

Fixes: 2b5a4b4b ("psy: axp288_fuel_gauge: Rework get_status()")
Signed-off-by: default avatarHans de Goede <hdegoede@redhat.com>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.co.uk>
parent 7638eb56
......@@ -343,7 +343,7 @@ static inline void fuel_gauge_remove_debugfs(struct axp288_fg_info *info)
static void fuel_gauge_get_status(struct axp288_fg_info *info)
{
int pwr_stat, fg_res;
int pwr_stat, fg_res, curr, ret;
pwr_stat = fuel_gauge_reg_readb(info, AXP20X_PWR_INPUT_STATUS);
if (pwr_stat < 0) {
......@@ -353,19 +353,42 @@ static void fuel_gauge_get_status(struct axp288_fg_info *info)
}
/* Report full if Vbus is valid and the reported capacity is 100% */
if (pwr_stat & PS_STAT_VBUS_VALID) {
fg_res = fuel_gauge_reg_readb(info, AXP20X_FG_RES);
if (fg_res < 0) {
dev_err(&info->pdev->dev,
"FG RES read failed: %d\n", fg_res);
return;
}
if (fg_res == (FG_REP_CAP_VALID | 100)) {
info->status = POWER_SUPPLY_STATUS_FULL;
return;
}
if (!(pwr_stat & PS_STAT_VBUS_VALID))
goto not_full;
fg_res = fuel_gauge_reg_readb(info, AXP20X_FG_RES);
if (fg_res < 0) {
dev_err(&info->pdev->dev, "FG RES read failed: %d\n", fg_res);
return;
}
if (!(fg_res & FG_REP_CAP_VALID))
goto not_full;
fg_res &= ~FG_REP_CAP_VALID;
if (fg_res == 100) {
info->status = POWER_SUPPLY_STATUS_FULL;
return;
}
/*
* Sometimes the charger turns itself off before fg-res reaches 100%.
* When this happens the AXP288 reports a not-charging status and
* 0 mA discharge current.
*/
if (fg_res < 90 || (pwr_stat & PS_STAT_BAT_CHRG_DIR))
goto not_full;
ret = iio_read_channel_raw(info->iio_channel[BAT_D_CURR], &curr);
if (ret < 0) {
dev_err(&info->pdev->dev, "FG get current failed: %d\n", ret);
return;
}
if (curr == 0) {
info->status = POWER_SUPPLY_STATUS_FULL;
return;
}
not_full:
if (pwr_stat & PS_STAT_BAT_CHRG_DIR)
info->status = POWER_SUPPLY_STATUS_CHARGING;
else
......