Commit f99c1b87 authored by Rafael J. Wysocki's avatar Rafael J. Wysocki

thermal: core: Rewrite comments in handle_thermal_trip()

Make the comments regarding trip crossing and threshold updates in
handle_thermal_trip() slightly more clear.

No functional impact.
Signed-off-by: default avatarRafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: default avatarLukasz Luba <lukasz.luba@arm.com>
Acked-by: default avatarDaniel Lezcano <daniel.lezcano@linaro.org>
parent b1ae92dc
......@@ -368,6 +368,13 @@ static void handle_thermal_trip(struct thermal_zone_device *tz,
if (trip->temperature == THERMAL_TEMP_INVALID)
return;
/*
* If the trip temperature or hysteresis has been updated recently,
* the threshold needs to be computed again using the new values.
* However, its initial value still reflects the old ones and that
* is what needs to be compared with the previous zone temperature
* to decide which action to take.
*/
if (tz->last_temperature == THERMAL_TEMP_INVALID) {
/* Initialization. */
td->threshold = trip->temperature;
......@@ -375,11 +382,9 @@ static void handle_thermal_trip(struct thermal_zone_device *tz,
td->threshold -= trip->hysteresis;
} else if (tz->last_temperature < td->threshold) {
/*
* The trip threshold is equal to the trip temperature, unless
* the latter has changed in the meantime. In either case,
* the trip is crossed if the current zone temperature is at
* least equal to its temperature, but otherwise ensure that
* the threshold and the trip temperature will be equal.
* There is no mitigation under way, so it needs to be started
* if the zone temperature exceeds the trip one. The new
* threshold is then set to the low temperature of the trip.
*/
if (tz->temperature >= trip->temperature) {
thermal_notify_tz_trip_up(tz, trip);
......@@ -390,14 +395,9 @@ static void handle_thermal_trip(struct thermal_zone_device *tz,
}
} else {
/*
* The previous zone temperature was above or equal to the trip
* threshold, which would be equal to the "low temperature" of
* the trip (its temperature minus its hysteresis), unless the
* trip temperature or hysteresis had changed. In either case,
* the trip is crossed if the current zone temperature is below
* the low temperature of the trip, but otherwise ensure that
* the trip threshold will be equal to the low temperature of
* the trip.
* Mitigation is under way, so it needs to stop if the zone
* temperature falls below the low temperature of the trip.
* In that case, the trip temperature becomes the new threshold.
*/
if (tz->temperature < trip->temperature - trip->hysteresis) {
thermal_notify_tz_trip_down(tz, trip);
......