Staging: comedi - correct parameter gainlkup for DAQCard-6024E in driver ni_mio_cs.c
commit ebe86223 upstream. Correct at least one of the incorrect specs for a national instrument data acquisition card DAQCard-6024E. This card has only four different gain settings (+-10V, +-5V, +-0.5V, +-0.05V). Signed-off-by: Martin Homuth-Rosemann <homuth-rosemann@gmx.net> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>