greybus: arche-platform: Make sure APB power cycles on coldboot
On first wake/detect pulse, everything works fine, as APB would be in poweroff state initially. But on subsequent wake/detect pulses, where APB is already in active state, internal function just returns doing nothing, as it finds that device is already in active state. So the solution would be to make sure that, whenever execution reaches to coldboot, make sure we power cycle it. Power off first, before powering on. Interrupt handler takes care of ignoring < 30msec pulses, so we should be safe here to power cycle APB. Testing Done: Testd on DB3.5 platform. Signed-off-by: Vaibhav Hiremath <vaibhav.hiremath@linaro.org> Signed-off-by: Greg Kroah-Hartman <gregkh@google.com>