• Jan Lindström's avatar
    Fix bug https://code.launchpad.net/~laurynas-biveinis/percona-server/bug1295268 · 50273380
    Jan Lindström authored
    (Inadequate background LRU flushing for write workloads with InnoDB compression).
      
      If InnoDB compression is used and the workload has writes, the
      following situation is possible. The LRU flusher issues an LRU flush
      request for an instance.  buf_do_LRU_batch decides to perform
      unzip_LRU eviction and this eviction might fully satisfy the
      request. Then buf_flush_LRU_tail checks the number of flushed pages in
      the last iteration, finds it to be zero, and wrongly decides not to
      flush that instance anymore.
      
      Fixed by maintaining unzip_LRU eviction counter in struct
      flush_counter_t variables, and checking it in buf_flush_LRU_tail when
      deciding whether to stop flushing the current instance.
    
    Added test cases for new configuration files to get mysql-test-run suite sys_vars
    to pass. Fix some small errors.
    50273380
innodb_use_lz4_basic.test 114 Bytes