- 13 Oct, 2013 2 commits
-
-
Michael Widenius authored
- Made slaves temporary table multi-thread slave safe by adding mutex around save_temporary_table usage. - rli->save_temporary_tables is the active list of all used temporary tables - This is copied to THD->temporary_tables when temporary tables are opened and updated when temporary tables are closed - Added THD->lock_temporary_tables() and THD->unlock_temporary_tables() to simplify this. - Relay_log_info->sql_thd renamed to Relay_log_info->sql_driver_thd to avoid wrong usage for merged code. - Added is_part_of_group() to mark functions that are part of the next function. This replaces setting IN_STMT when events are executed. - Added is_begin(), is_commit() and is_rollback() functions to Query_log_event to simplify code. - If slave_skip_counter is set run things in single threaded mode. This simplifies code for skipping events. - Updating state of relay log (IN_STMT and IN_TRANSACTION) is moved to one single function: update_state_of_relay_log() We can't use OPTION_BEGIN to check for the state anymore as the sql_driver and sql execution threads may be different. Clear IN_STMT and IN_TRANSACTION in init_relay_log_pos() and Relay_log_info::cleanup_context() to ensure the flags doesn't survive slave restarts is_in_group() is now independent of state of executed transaction. - Reset thd->transaction.all.modified_non_trans_table() if we did set it for single table row events. This was mainly for keeping the flag as documented. - Changed slave_open_temp_tables to uint32 to be able to use atomic operators on it. - Relay_log_info::sleep_lock -> rpl_group_info::sleep_lock - Relay_log_info::sleep_cond -> rpl_group_info::sleep_cond - Changed some functions to take rpl_group_info instead of Relay_log_info to make them multi-slave safe and to simplify usage - do_shall_skip() - continue_group() - sql_slave_killed() - next_event() - Simplifed arguments to io_salve_killed(), check_io_slave_killed() and sql_slave_killed(); No reason to supply THD as this is part of the given structure. - set_thd_in_use_temporary_tables() removed as in_use is set on usage - Added information to thd_proc_info() which thread is waiting for slave mutex to exit. - In open_table() reuse code from find_temporary_table() Other things: - More DBUG statements - Fixed the rpl_incident.test can be run with --debug - More comments - Disabled not used function rpl_connect_master() mysql-test/suite/perfschema/r/all_instances.result: Moved sleep_lock and sleep_cond to rpl_group_info mysql-test/suite/rpl/r/rpl_incident.result: Updated result mysql-test/suite/rpl/t/rpl_incident-master.opt: Not needed anymore mysql-test/suite/rpl/t/rpl_incident.test: Fixed that test can be run with --debug sql/handler.cc: More DBUG_PRINT sql/log.cc: More comments sql/log_event.cc: Added DBUG statements do_shall_skip(), continue_group() now takes rpl_group_info param Use is_begin(), is_commit() and is_rollback() functions instead of inspecting query string We don't have set slaves temporary tables 'in_use' as this is now done when tables are opened. Removed IN_STMT flag setting. This is now done in update_state_of_relay_log() Use IN_TRANSACTION flag to test state of relay log. In rows_event_stmt_cleanup() reset thd->transaction.all.modified_non_trans_table if we had set this before. sql/log_event.h: do_shall_skip(), continue_group() now takes rpl_group_info param Added is_part_of_group() to mark events that are part of the next event. This replaces setting IN_STMT when events are executed. Added is_begin(), is_commit() and is_rollback() functions to Query_log_event to simplify code. sql/log_event_old.cc: Removed IN_STMT flag setting. This is now done in update_state_of_relay_log() do_shall_skip(), continue_group() now takes rpl_group_info param sql/log_event_old.h: Added is_part_of_group() to mark events that are part of the next event. do_shall_skip(), continue_group() now takes rpl_group_info param sql/mysqld.cc: Changed slave_open_temp_tables to uint32 to be able to use atomic operators on it. Relay_log_info::sleep_lock -> Rpl_group_info::sleep_lock Relay_log_info::sleep_cond -> Rpl_group_info::sleep_cond sql/mysqld.h: Updated types and names sql/rpl_gtid.cc: More DBUG sql/rpl_parallel.cc: Updated TODO section Set thd for event that is execution Use new is_begin(), is_commit() and is_rollback() functions. More comments sql/rpl_rli.cc: sql_thd -> sql_driver_thd Relay_log_info::sleep_lock -> rpl_group_info::sleep_lock Relay_log_info::sleep_cond -> rpl_group_info::sleep_cond Clear IN_STMT and IN_TRANSACTION in init_relay_log_pos() and Relay_log_info::cleanup_context() to ensure the flags doesn't survive slave restarts. Reset table->in_use for temporary tables as the table may have been used by another THD. Use IN_TRANSACTION instead of OPTION_BEGIN to check state of relay log. Removed IN_STMT flag setting. This is now done in update_state_of_relay_log() sql/rpl_rli.h: Changed relay log state flags to bit masks instead of bit positions (most other code we have uses bit masks) Added IN_TRANSACTION to mark if we are in a BEGIN ... COMMIT section. save_temporary_tables is now thread safe Relay_log_info::sleep_lock -> rpl_group_info::sleep_lock Relay_log_info::sleep_cond -> rpl_group_info::sleep_cond Relay_log_info->sql_thd renamed to Relay_log_info->sql_driver_thd to avoid wrong usage for merged code is_in_group() is now independent of state of executed transaction. sql/slave.cc: Simplifed arguments to io_salve_killed(), sql_slave_killed() and check_io_slave_killed(); No reason to supply THD as this is part of the given structure. set_thd_in_use_temporary_tables() removed as in_use is set on usage in sql_base.cc sql_thd -> sql_driver_thd More DBUG Added update_state_of_relay_log() which will calculate the IN_STMT and IN_TRANSACTION state of the relay log after the current element is executed. If slave_skip_counter is set run things in single threaded mode. Simplifed arguments to io_salve_killed(), check_io_slave_killed() and sql_slave_killed(); No reason to supply THD as this is part of the given structure. Added information to thd_proc_info() which thread is waiting for slave mutex to exit. Disabled not used function rpl_connect_master() Updated argument to next_event() sql/sql_base.cc: Added mutex around usage of slave's temporary tables. The active list is always kept up to date in sql->rgi_slave->save_temporary_tables. Clear thd->temporary_tables after query (safety) More DBUG When using temporary table, set table->in_use to current thd as the THD may be different for slave threads. Some code is ifdef:ed with REMOVE_AFTER_MERGE_WITH_10 as the given code in 10.0 is not yet in this tree. In open_table() reuse code from find_temporary_table() sql/sql_binlog.cc: rli->sql_thd -> rli->sql_driver_thd Remove duplicate setting of rgi->rli sql/sql_class.cc: Added helper functions rgi_lock_temporary_tables() and rgi_unlock_temporary_tables() Would have been nicer to have these inline, but there was no easy way to do that sql/sql_class.h: Added functions to protect slaves temporary tables sql/sql_parse.cc: Added DBUG_PRINT sql/transaction.cc: Added comment
-
Michael Widenius authored
This helps when moving from MariaDB 5.5 to MariaDB 10.0 as sometimes the log file size is rounded differently. storage/innobase/srv/srv0start.c: Give a warning, not an error, if the log file size in innodb doesn't match what is on disk storage/xtradb/srv/srv0start.c: Give a warning, not an error, if the log file size in innodb doesn't match what is on disk
-
- 08 Oct, 2013 1 commit
-
-
unknown authored
Improve STOP SLAVE in parallel mode. Now, the parallel part will queue the current event group to the end, and then stop queing any more events. Each worker will complete the current event group, and then just skip any further queued events.
-
- 30 Sep, 2013 1 commit
-
-
unknown authored
-
- 23 Sep, 2013 2 commits
- 19 Sep, 2013 2 commits
- 17 Sep, 2013 2 commits
- 16 Sep, 2013 1 commit
-
-
unknown authored
Add a simple test case. Fix bugs found.
-
- 13 Sep, 2013 1 commit
-
-
unknown authored
Some after-review fixes.
-
- 12 Jul, 2013 3 commits
-
-
unknown authored
Move annotate-event stuff from Relay_log_info to rpl_group_info, to make it thread safe.
-
unknown authored
Remove Relay_log_info::group_info. (It is not thread safe).
-
unknown authored
Move the deferred event stuff from Relay_log_info to rpl_group_info to make it thread safe for parallel replication.
-
- 09 Jul, 2013 1 commit
-
-
unknown authored
Fix a number of failures in the test suite.
-
- 08 Jul, 2013 1 commit
-
-
unknown authored
Fix a bunch of issues found with locking, ordering, and non-thread-safe stuff in Relay_log_info. Now able to do a simple benchmark, showing 4.5 times speedup for applying a binlog with 10000 REPLACE statements.
-
- 04 Jul, 2013 3 commits
-
-
unknown authored
Impement options --binlog-commit-wait-count and --binlog-commit-wait-usec. These options permit the DBA to deliberately increase latency of an individual commit to get more transactions in each binlog group commit. This increases the opportunity for parallel replication on the slave, and can also decrease I/O load on the master. The options also make it easier to test the parallel replication with mysql-test-run.
-
unknown authored
Fix some bugs around waiting for worker threads to end during SQL slave stop. Free Log_event after parallel execution (still needs to be made thread-safe by using rpl_group_info rather than rli).
-
unknown authored
Wait for all worker threads to finish when stopping the SQL thread. (Only a basic wait; this still needs to be fixed to include timeout logic as in sql_slave_killed()).
-
- 03 Jul, 2013 2 commits
-
-
unknown authored
Pass down rpl_group_info * to remove one instance of non-threadsafe use of rli->group_info.
-
unknown authored
Hook in the wait-for-prior-commit logic (not really tested yet). Clean up some resource maintenance around rpl_group_info (may still be some smaller issues there though). Add a ToDo list at the top of rpl_parallel.cc
-
- 28 Jun, 2013 1 commit
-
-
unknown authored
First step of splitting out part of Relay_log_info, so that different event groups being applied in parallel can each use their own copy.
-
- 26 Jun, 2013 1 commit
-
-
unknown authored
Implement facility for the commit in one thread to wait for the commit of another to complete first. The wait is done in a way that does not hinder that a waiter and a waitee can group commit together with a single fsync() in both binlog and InnoDB. The wait is done efficiently with respect to locking. The patch was originally made to support TaoBao parallel replication with in-order commit; now it will be adapted to also be used for parallel replication of group-committed transactions. A waiter THD registers itself with a prior waitee THD. The waiter will then complete its commit at the earliest in the same group commit of the waitee (when using binlog). The wait can also be done explicitly by the waitee.
-
- 25 Jun, 2013 2 commits
- 24 Jun, 2013 1 commit
-
-
unknown authored
First very rough sketch. We spawn and retire a pool of slave threads. Test main.alias works, most likely not much else does.
-
- 08 Jun, 2013 1 commit
-
-
unknown authored
-
- 07 Jun, 2013 4 commits
-
-
unknown authored
Now whenever we reach the GTID point requested from the slave (when using GTID position to connect), we send a fake Gtid_list event. This event is used by the slave to know the current old-style position for MASTER_POS_WAIT(), and later the similar binlog position for MASTER_GTID_WAIT(). Without this fake event, if the slave is already fully up-to-date with the master, there may be no events sent at the given position for an indeterminate time.
-
unknown authored
If the mysql.gtid_slave_pos table is not available, we cannot load nor update the current GTID position persistently. This can happen eg. after an upgrade, before mysql_upgrade_db is run, or if the table is InnoDB and the server is restarted without the InnoDB storage engine enabled. Before, replication always failed to start if the table was unavailable. With this patch, we try to continue with old-style replication, after suitable complaints in the error log. In strict mode, or if slave is configured to use GTID, slave still refuses to start.
-
unknown authored
Now we give an error on attempts to set @@SESSION.gtid_domain_id or @@SESSION.gtid_seq_no when a transaction is active.
-
unknown authored
There was some old code that cleared the position in CHANGE MASTER, it was forgotten to be removed. In addition, add code that saves/restores the old-style position when we nuke the old relay logs as part of GTID slave start. Normally we will not use these, but it could be useful in case the GTID connect fails and user wants to go back to the old-style coordinates.
-
- 06 Jun, 2013 3 commits
-
-
Sergei Golubchik authored
-
Vladislav Vaintroub authored
-
Michael Widenius authored
mysql-test/include/wait_show_condition.inc: Print failing statement if timeout mysql-test/r/myisam-metadata.result: Updated DBUG_SYNC mysql-test/t/myisam-metadata.test: Updated DBUG_SYNC. Removed wait_show_condtion, as this is not needed when we use DBUG_SYNC This should fix timing issues with the test mysys/thr_mutex.c: Added comments sql/sql_acl.cc: atoi -> atoll() (Safety) storage/myisam/ha_myisam.cc: Send signal before mi_repair_by_sort.
-
- 05 Jun, 2013 2 commits
-
-
unknown authored
-
unknown authored
Fix problems related to reconnect. When we need to reconnect (ie. explict stop/start of just the IO thread by user, or automatic reconnect due to loosing network connection with the master), it is a bit complex to correctly resume at the right point without causing duplicate or missing events in the relay log. The previous code had multiple problems in this regard. With this patch, the problem is solved as follows. The IO thread keeps track (in memory) of which GTID was last queued to the relay log. If it needs to reconnect, it resumes at that GTID position. It also counts number of events received within the last, possibly partial, event group, and skips the same number of events after a reconnect, so that events already enqueued before the reconnect are not duplicated. (There is no need to keep any persistent state; whenever we restart slave threads after both of them being stopped (such as after server restart), we erase the relay logs and start over from the last GTID applied by SQL thread. But while the SQL thread is running, this patch is needed to get correct relay log).
-
- 03 Jun, 2013 1 commit
-
-
unknown authored
There were several cases where the slave GTID position was not loaded correctly before being used. This caused various failures such as corrupting the position at slave start and empty values of @@gtid_slave_pos and @@gtid_current_pos. Fixed by adding more checks for loaded position, and by always loading the position at server startup.
-
- 01 Jun, 2013 2 commits
-
-
Vladislav Vaintroub authored
-
Vladislav Vaintroub authored
Problem : libreadline.so was already present on the machine, however the cmake check NEW_READLINE_INTERFACE was unsuccessfull indicating, thus bundled library had to be used instead of system library. The problem was that the value for HAVE_HIST_ENTRY cmake variable was cached with incorrect value (1 on NetBSD). The fix is to change HAVE_HIST_ENTRY to 0 with CACHE FORCE, after switching to bundled readline.
-