- 04 Aug, 2010 4 commits
-
-
Alexander Nozdrin authored
-
Alexander Nozdrin authored
-
Alexander Nozdrin authored
-
Alexander Nozdrin authored
-
- 03 Aug, 2010 9 commits
-
-
Georgi Kodinov authored
-
Georgi Kodinov authored
The enum system variables were handled inconsistently as ints, unsigned int and unsigned long on various places. This caused problems on platforms on which sizeof(int) != sizeof(long). Fixed by homogenizing the type of the enum variables to unsigned int, since it's size compatible with the C enum type. Removed the test from the experimental list.
-
Alfranio Correia authored
The problem reported in BUG#55625 does not happen in mysql-trunk when the logging format is row. However, a "CREATE SELECT" that fails when the logging format is statement is not written to the binary log. This problem will be addressed in BUG#47899.
-
Georgi Kodinov authored
-
Alfranio Correia authored
-
unknown authored
Post fix mysql-test/t/mysqlbinlog.test: Updated for Bug#34283
-
unknown authored
Post fix mysql-test/t/mysqlbinlog.test: Updated for Bug#34283
-
unknown authored
With statement- or mixed-mode logging, "LOAD DATA INFILE" queries are written to the binlog using special types of log events. When mysqlbinlog reads such events, it re-creates the file in a temporary directory with a generated filename and outputs a "LOAD DATA INFILE" query where the filename is replaced by the generated file. The temporary file is not deleted by mysqlbinlog after termination. To fix the problem, in mixed mode we go to row-based. In SBR, we document it to remind user the tmpfile is left in a temporary directory. mysql-test/suite/binlog/r/binlog_mixed_load_data.result: Test result for BUG#34283. mysql-test/suite/binlog/t/binlog_killed_simulate.test: Updated for BUg#34283 mysql-test/suite/binlog/t/binlog_mixed_load_data.test: Added the test file to verify that 'load data infile...' statement will go to row-based in mixed mode. mysql-test/suite/binlog/t/binlog_stm_blackhole.test: Updated for BUg#34283 mysql-test/suite/rpl/r/rpl_innodb_mixed_dml.result: Updated for Bug#34283 mysql-test/suite/rpl/t/rpl_loaddata.test: Updated for Bug#34283 mysql-test/suite/rpl/t/rpl_loaddata_fatal.test: Updated for Bug#34283 mysql-test/suite/rpl/t/rpl_loaddata_map.test: Updated for Bug#34283 mysql-test/suite/rpl/t/rpl_slave_load_remove_tmpfile.test: Updated for Bug#34283 mysql-test/suite/rpl/t/rpl_stm_log.test: Updated for B mysys/stacktrace.c: Auto merge sql/sql_lex.cc: Auto merg sql/sql_load.cc: Added code to go to row-based in mixed mode for 'load data infile ...' statement
-
unknown authored
With statement- or mixed-mode logging, "LOAD DATA INFILE" queries are written to the binlog using special types of log events. When mysqlbinlog reads such events, it re-creates the file in a temporary directory with a generated filename and outputs a "LOAD DATA INFILE" query where the filename is replaced by the generated file. The temporary file is not deleted by mysqlbinlog after termination. To fix the problem, in mixed mode we go to row-based. In SBR, we document it to remind user the tmpfile is left in a temporary directory. mysql-test/extra/rpl_tests/rpl_loaddata.test: Updated for Bug#34283 mysql-test/suite/binlog/r/binlog_mixed_load_data.result: Test result for BUG#34283. mysql-test/suite/binlog/t/binlog_killed_simulate.test: Updated for Bug#34283 mysql-test/suite/binlog/t/binlog_mixed_load_data.test: Added the test file to verify that 'load data infile...' statement will go to row-based in mixed mode. mysql-test/suite/binlog/t/binlog_stm_blackhole.test: Updated for Bug#34283 mysql-test/suite/rpl/r/rpl_innodb_mixed_dml.result: Updated for Bug#34283 mysql-test/suite/rpl/t/rpl_loaddata_fatal.test: Updated for Bug#34283 mysql-test/suite/rpl/t/rpl_loaddata_map.test: Updated for Bug#34283 mysql-test/suite/rpl/t/rpl_slave_load_remove_tmpfile.test: Updated for Bug#34283 mysql-test/suite/rpl/t/rpl_stm_log.test: Updated for Bug#34283 sql/sql_load.cc: Added code to go to row-based in mixed mode for 'load data infile ...' statement
-
- 02 Aug, 2010 6 commits
-
-
Alfranio Correia authored
A CREATE...SELECT that fails is written to the binary log if a non-transactional statement is updated. If the logging format is ROW, the CREATE statement and the changes are written to the binary log as distinct events and by consequence the created table is not rolled back in the slave. In this patch, we opted to let the slave goes out of sync by not writting to the binary log the CREATE statement. We do this by simply reseting the binary log's cache. mysql-test/suite/rpl/r/rpl_drop.result: Added a test case. mysql-test/suite/rpl/t/rpl_drop.test: Added a test case. sql/log.cc: Introduced a function to clean up the cache. sql/log.h: Introduced a function to clean up the cache. sql/sql_insert.cc: Cleaned up the binary log cache if a CREATE...SELECT fails.
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
- 01 Aug, 2010 1 commit
-
-
Gleb Shchepa authored
Queries may crash, if 1) the GREATEST or the LEAST function has a mixed list of numeric and LONGBLOB arguments and 2) the result of such a function goes through an intermediate temporary table. An Item that references a LONGBLOB field has max_length of UINT_MAX32 == (2^32 - 1). The current implementation of GREATEST/LEAST returns REAL result for a mixed list of numeric and string arguments (that contradicts with the current documentation, this contradiction was discussed and it was decided to update the documentation). The max_length of such a function call was calculated as a maximum of argument max_length values (i.e. UINT_MAX32). That max_length value of UINT_MAX32 was used as a length for the intermediate temporary table Field_double to hold GREATEST/LEAST function result. The Field_double::val_str() method call on that field allocates a String value. Since an allocation of String reserves an additional byte for a zero-termination, the size of String buffer was set to (UINT_MAX32 + 1), that caused an integer overflow: actually, an empty buffer of size 0 was allocated. An initialization of the "first" byte of that zero-size buffer with '\0' caused a crash. The Item_func_min_max::fix_length_and_dec() has been modified to calculate max_length for the REAL result like we do it for arithmetical operators. ****** Bug #54461: crash with longblob and union or update with subquery Queries may crash, if 1) the GREATEST or the LEAST function has a mixed list of numeric and LONGBLOB arguments and 2) the result of such a function goes through an intermediate temporary table. An Item that references a LONGBLOB field has max_length of UINT_MAX32 == (2^32 - 1). The current implementation of GREATEST/LEAST returns REAL result for a mixed list of numeric and string arguments (that contradicts with the current documentation, this contradiction was discussed and it was decided to update the documentation). The max_length of such a function call was calculated as a maximum of argument max_length values (i.e. UINT_MAX32). That max_length value of UINT_MAX32 was used as a length for the intermediate temporary table Field_double to hold GREATEST/LEAST function result. The Field_double::val_str() method call on that field allocates a String value. Since an allocation of String reserves an additional byte for a zero-termination, the size of String buffer was set to (UINT_MAX32 + 1), that caused an integer overflow: actually, an empty buffer of size 0 was allocated. An initialization of the "first" byte of that zero-size buffer with '\0' caused a crash. The Item_func_min_max::fix_length_and_dec() has been modified to calculate max_length for the REAL result like we do it for arithmetical operators. mysql-test/r/func_misc.result: Test case for bug #54461. ****** Test case for bug #54461. mysql-test/t/func_misc.test: Test case for bug #54461. ****** Test case for bug #54461. sql/item_func.cc: Bug #54461: crash with longblob and union or update with subquery The Item_func_min_max::fix_length_and_dec() has been modified to calculate max_length for the REAL result like we do it for arithmetical operators. ****** Bug #54461: crash with longblob and union or update with subquery The Item_func_min_max::fix_length_and_dec() has been modified to calculate max_length for the REAL result like we do it for arithmetical operators.
-
- 31 Jul, 2010 3 commits
-
-
Alexander Nozdrin authored
-
Alexander Nozdrin authored
-
Alexander Nozdrin authored
-
- 30 Jul, 2010 17 commits
-
-
Davi Arnaut authored
scripts if cmake is available. We need to always generate the scripts in order for the dual cmake/autotools support to work.
-
Davi Arnaut authored
Fix compiler warnings. mysys/stacktrace.c: Tag unused parameters. sql/sql_lex.cc: Variable becomes unused in non-debug builds. Also, no need to assert the obvious.
-
Alexander Nozdrin authored
-
Alexander Nozdrin authored
****** This patch fixes the following bugs: - Bug#5889: Exit handler for a warning doesn't hide the warning in trigger - Bug#9857: Stored procedures: handler for sqlwarning ignored - Bug#23032: Handlers declared in a SP do not handle warnings generated in sub-SP - Bug#36185: Incorrect precedence for warning and exception handlers The problem was in the way warnings/errors during stored routine execution were handled. Prior to this patch the logic was as follows: - when a warning/an error happens: if we're executing a stored routine, and there is a handler for that warning/error, remember the handler, ignore the warning/error and continue execution. - after a stored routine instruction is executed: check for a remembered handler and activate one (if any). This logic caused several problems: - if one instruction generates several warnings (errors) it's impossible to choose the right handler -- a handler for the first generated condition was chosen and remembered for activation. - mess with handling conditions in scopes different from the current one. - not putting generated warnings/errors into Warning Info (Diagnostic Area) is against The Standard. The patch changes the logic as follows: - Diagnostic Area is cleared on the beginning of each statement that either is able to generate warnings, or is able to work with tables. - at the end of a stored routine instruction, Diagnostic Area is left intact. - Diagnostic Area is checked after each stored routine instruction. If an instruction generates several condition, it's now possible to take a look at all of them and determine an appropriate handler. mysql-test/r/signal.result: Update result file: 1. handled conditions are not cleared any more; 2. reflect changes in signal.test mysql-test/r/signal_demo3.result: Update result file: handled conditions are not cleared any more. Due to playing with max_error_count, resulting warning lists have changed. mysql-test/r/sp-big.result: Update result file: handled conditions are not cleared any more. mysql-test/r/sp-bugs.result: Update result file: handled conditions are not cleared any more. mysql-test/r/sp-code.result: Update result file: 1. handled conditions are not cleared any more. 2. add result for a new test case in sp-code.test. mysql-test/r/sp-error.result: Update result file: 1. handled conditions are not cleared any more. 2. add result for a new test case in sp-error.test. mysql-test/r/sp.result: Update result file: handled conditions are not cleared any more. mysql-test/r/sp_trans.result: Update result file: handled conditions are not cleared any more. mysql-test/r/strict.result: Update result file: handled conditions are not cleared any more. mysql-test/r/view.result: Update result file: handled conditions are not cleared any more. mysql-test/suite/funcs_1/r/innodb_storedproc_02.result: Update result file: handled conditions are not cleared any more. mysql-test/suite/funcs_1/r/memory_storedproc_02.result: Update result file: handled conditions are not cleared any more. mysql-test/suite/funcs_1/r/myisam_storedproc_02.result: Update result file: handled conditions are not cleared any more. mysql-test/suite/funcs_1/r/storedproc.result: Update result file: handled conditions are not cleared any more. mysql-test/suite/rpl/r/rpl_row_sp005.result: Update result file: handled conditions are not cleared any more. mysql-test/suite/rpl/r/rpl_row_sp006_InnoDB.result: Update result file: handled conditions are not cleared any more. mysql-test/suite/rpl/r/rpl_row_trig003.result: Update result file: handled conditions are not cleared any more. mysql-test/t/signal.test: Make a test case more readable in the result file. mysql-test/t/sp-code.test: Add a test case for Bug#23032 checking that No Data takes precedence on Warning. mysql-test/t/sp-error.test: Adding test cases for: - Bug#23032 - Bug#36185 - Bug#5889 - Bug#9857 mysql-test/t/sp.test: Fixing test case to reflect behavioral changes made by the patch. sql/sp_head.cc: Reset the per-statement warning count before executing a stored procedure instruction. Move to a separate function code which checks the completion status of the executed statement and searches for a handler. Remove redundant code now that search for a handler is done after execution, errors are always pushed. sql/sp_pcontext.h: Remove unused code. sql/sp_rcontext.cc: - Polish sp_rcontext::find_handler(): use sp_rcontext::m_hfound instead of an extra local variable; - Remove sp_rcontext::handle_condition(); - Introduce sp_rcontext::activate_handler(), which prepares previously found handler for execution. - Move sp_rcontext::enter_handler() code into activate_handler(), because enter_handler() is used only from there; - Cleanups; - Introduce DBUG_EXECUTE_IF() for a test case in sp-code.test sql/sp_rcontext.h: - Remove unused code - Cleanups sql/sql_class.cc: Merge THD::raise_condition_no_handler() into THD::raise_condition(). After the patch raise_condition_no_handler() was called in raise_condition() only. sql/sql_class.h: Remove raise_condition_no_handler(). sql/sql_error.cc: Remove Warning_info::reserve_space() -- handled conditions are not cleared any more, so there is no need for RESIGNAL to re-push them. sql/sql_error.h: Remove Warning_info::reserve_space(). sql/sql_signal.cc: Handled conditions are not cleared any more, so there is no need for RESIGNAL to re-push them.
-
Alexander Nozdrin authored
-
Luis Soares authored
-
Luis Soares authored
-
Luis Soares authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Luis Soares authored
Revert BUG#34283. Conflicts ========= Text conflict in sql/sql_load.cc 1 conflicts encountered.
-
Luis Soares authored
mostly because existing test result files were not updated.
-
Georgi Kodinov authored
In order to be able to check if the set of the grouping fields in a GROUP BY has changed (and thus to start a new group) the optimizer caches the current values of these fields in a set of Cached_item derived objects. The Cached_item_str, used for caching varchar and TEXT columns, is limited in length by the max_sort_length variable. A String buffer to store the value with an alloced length of either the max length of the string or the value of max_sort_length (whichever is smaller) in Cached_item_str's constructor. Then, at compare time the value of the string to compare to was truncated to the alloced length of the string buffer inside Cached_item_str. This is all fine and valid, but only if you're not assigning values near or equal to the alloced length of this buffer. Because when assigning values like this the alloced length is rounded up and as a result the next set of data will not match the group buffer, thus leading to wrong results because of the changed alloced_length. Fixed by preserving the original maximum length in the Cached_item_str's constructor and using this instead of the alloced_length to limit the string to compare to. Test case added.
-
Davi Arnaut authored
-
Davi Arnaut authored
-
Davi Arnaut authored
Fix a regression (due to a typo) which caused spurious incorrect argument errors for long data stream parameters if all forms of logging were disabled (binary, general and slow logs). sql/sql_prepare.cc: Add a missing logical NOT operator.
-