• Gavin Shan's avatar
    net/ncsi: Fix stale link state of inactive channels on failover · 008a424a
    Gavin Shan authored
    The issue was found on BCM5718 which has two NCSI channels in one
    package: C0 and C1. Both of them are connected to different LANs,
    means they are in link-up state and C0 is chosen as the active one
    until resetting BCM5718 happens as below.
    
    Resetting BCM5718 results in LSC (Link State Change) AEN packet
    received on C0, meaning LSC AEN is missed on C1. When LSC AEN packet
    received on C0 to report link-down, it fails over to C1 because C1
    is in link-up state as software can see. However, C1 is in link-down
    state in hardware. It means the link state is out of synchronization
    between hardware and software, resulting in inappropriate channel (C1)
    selected as active one.
    
    This resolves the issue by sending separate GLS (Get Link Status)
    commands to all channels in the package before trying to do failover.
    The last link states of all channels in the package are retrieved.
    With it, C0 (not C1) is selected as active one as expected.
    Signed-off-by: default avatarGavin Shan <gwshan@linux.vnet.ibm.com>
    Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
    008a424a