Stevens, Nick authored
The mcp3021 scaling code is dividing the VDD (full-scale) value in millivolts by the A2D resolution to obtain the scaling factor. When VDD is 3300mV (the standard value) and the resolution is 12-bit (4096 divisions), the result is a scale factor of 3300/4096, which is always one. Effectively, the raw A2D reading is always being returned because no scaling is applied. This patch fixes the issue and simplifies the register-to-volts calculation, removing the unneeded "output_scale" struct member. Signed-off-by: Nick Stevens <Nick.Stevens@digi.com> Cc: stable@vger.kernel.org # v3.10+ [Guenter Roeck: Dropped unnecessary value check] Signed-off-by: Guenter Roeck <linux@roeck-us.net>