Steve Wise authored
In __flush_qp(), the CQ ARMED bit was being cleared regardless of whether any notification is actually needed. This resulted in the iser termination logic getting stuck in ib_drain_sq() because the CQ was not marked ARMED and thus the drain CQE notification wasn't triggered. This new bug was exposed when this commit was merged: commit cbb40fad ("iw_cxgb4: only call the cq comp_handler when the cq is armed") Signed-off-by: Steve Wise <swise@opengridcomputing.com> Signed-off-by: Jason Gunthorpe <jgg@mellanox.com>