It seems that some batteries (noticed on DELL JYPJ136) assume capacity_now = design_capacity when fully charged. This causes reported capacity to suddenly jump to >full_charge_capacity (and that means capacity reported to userspace is >100% and incorrect) values after 99%. This patch detects capacity_now > full_charge_capacity, notifies userspace (unless it is the known bug where capacity_now == design_capacity) and trims the value to full_charge_capacity. Signed-off-by: Josef Gajdusek <atx@atx.name> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>