• Viresh Kumar's avatar
    ARM: dts: omap5: Add missing cooling device properties for CPUs · 484d578b
    Viresh Kumar authored
    The cooling device properties, like "#cooling-cells" and
    "dynamic-power-coefficient", should either be present for all the CPUs
    of a cluster or none. If these are present only for a subset of CPUs of
    a cluster then things will start falling apart as soon as the CPUs are
    brought online in a different order. For example, this will happen
    because the operating system looks for such properties in the CPU node
    it is trying to bring up, so that it can register a cooling device.
    
    Add such missing properties.
    
    Fix other missing properties (clocks, supply, clock latency) as well to
    make it all work.
    Signed-off-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
    Signed-off-by: default avatarTony Lindgren <tony@atomide.com>
    484d578b
omap5.dtsi 29.2 KB