Benjamin Gaignard authored
One of the features of STM32 trigger hardware block is a quadrature encoder that can counts up/down depending of the levels and edges of the selected external pins. This patch allow to read/write the counter, get it direction, set/get quadrature modes and get scale factor. When counting up preset value is the limit of the counter. When counting down the counter start from preset value down to 0. This preset value could be set/get by using /sys/bus/iio/devices/iio:deviceX/in_count0_preset attribute. Signed-off-by: Benjamin Gaignard <benjamin.gaignard@st.com> Reviewed-by: William Breathitt Gray <vilhelm.gray@gmail.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
4adec7da