Axel Lin authored
According to the datasheet, the voltage for twl6030ldo_ops is not linear for all cases. Linear mapping is only for the selection code from 00000001 to 00011000. Table 9. LDO Output Voltage Selection Code CODE VOUT(V) COD VOUT(V) CODE VOUT(V) CODE VOUT(V) 00000000 0 00001000 1.7 00010000 2.5 00011000 3.3 00000001 1.0 00001001 1.8 00010001 2.6 00011001 Reserved 00000010 1.1 00001010 1.9 00010010 2.7 00011010 Reserved 00000011 1.2 00001011 2.0 00010011 2.8 00011011 Reserved 00000100 1.3 00001100 2.1 00010100 2.9 00011100 Reserved 00000101 1.4 00001101 2.2 00010101 3.0 00011101 Reserved 00000110 1.5 00001110 2.3 00010110 3.1 00011110 Reserved 00000111 1.6 00001111 2.4 00010111 3.2 00011111 2.75 This patch implements the list_voltage callback based on above table. Signed-off-by: Axel Lin <axel.lin@gmail.com> Tested-by: Rajendra Nayak <rnayak@ti.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
c6a717c9