-
Chris Brandt authored
When there is no status bit, it is possible for the clock enable/disable operation to have not completed by the time the driver code resumes execution. This is due to the fact that write operations are sometimes queued and delayed internally. Doing a read ensures the write operations has completed. Fixes: b6face40 ("ARM: shmobile: r7s72100: add essential clock nodes to dtsi") Signed-off-by: Chris Brandt <chris.brandt@renesas.com> Reviewed-by: Geert Uytterhoeven <geert+renesas@glider.be> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>
f59de563