Ondrej Zary authored
Host reset oopses because it calls wd719x_chip_init, which calls request_firmware, under a spinlock. Stop the RISC first, then flush active SCBs under a spinlock. Finally call wd719x_chip_init unlocked. Also found and fixed more bugs during tests: Affected active SCBs were not flushed during abort, bus and device reset. This caused problems in a following host reset (hang or oops). Device and bus reset failed under load because the result of the reset command is WD719X_SUE_TERM or WD719X_SUE_RESET. Don't treat these codes as error in wd719x_wait_done. wd719x_direct_cmd for RESET/ABORT commands didn't work properly, causing timeouts. Looks like it was caused by the WD719X_DISABLE_INT bit. Not setting it for RESET/ABORT commands seems to fix the probem. Also lower the log level of the corresponding "direct command completed" message to debug. Unfortunately, my documentation is missing some pages, including page 67 (SPIDER67.gif) about resets :( Reported-by: Hariprasad Kelam <hariprasad.kelam@gmail.com> Signed-off-by: Ondrej Zary <linux@zary.sk> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>