    Testing has revealed that the temperature in the rtp controller of the A10
    (sun4i) SoC has a different curve then on the A13 (sun5i) and later models.
    
    Add a new sun5i-a13-ts compatible to differentiate the newer models and
    set the curve based on the compatible string.
    
    The new curve is still not ideal on all A10-s, that seems to have to
    do with there being a large spread between different A10-s out there,
    the new curve us based on callibration results on 4 completely different
    models:
                            raw min raw max temp min temp max stepsize offset
    Tong Zhang's hackberry    2402    2680    45.0     80.0    0.125   -255.3
    Hansg's Cubieboard        2207    2300    36.0     45.0    0.096   -175.8
    Olliver's lime 1 (*):     2258    2537    48.3     87.1    0.139   -265.7
    Olliver's lime 2 (*):     2222    2486    46.7     91.7    0.170   -331.0
    *) from: http://linux-sunxi.org/Temperature_Calibration
    
    Average all 4:                                             0.133   -257.0
    Average without outliers (middle 2):                       0.132   -261.0
    
    Since it is better to slightly overreport the temperature this patch uses
    the average of all 4 as curve.
    
    This fixes the temperature reported on the A10 being much higher then
    expected.
    Reported-by: default avatarTong Zhang <lovewilliam@gmail.com>
    Signed-off-by: default avatarHans de Goede <hdegoede@redhat.com>
    Signed-off-by: default avatarDmitry Torokhov <dmitry.torokhov@gmail.com>