    ARM: shmobile: lager: phy fixup needs CONFIG_PHYLIB · 6802cdc5
    Simon Horman authored
    Do not build the phy fixup unless CONFIG_PHYLIB is enabled.
    
    Other than not being useful it is also not possible to link
    the code under this condition as phy_register_fixup_for_id(),
    mdiobus_read() and mdiobus_write() are absent.
    
    arch/arm/mach-shmobile/built-in.o: In function `lager_ksz8041_fixup':
    board-lager.c:(.text+0xb8): undefined reference to `mdiobus_read'
    board-lager.c:(.text+0xd4): undefined reference to `mdiobus_write'
    arch/arm/mach-shmobile/built-in.o: In function `lager_init':
    board-lager.c:(.init.text+0xafc): undefined reference to `phy_register_fixup_for_id'
    
    This problem was introduced by 48c8b96f
    ("ARM: shmobile: Lager: add Micrel KSZ8041 PHY fixup")
    
    Cc: Sergei Shtylyov <sergei.shtylyov@cogentembedded.com>
    Signed-off-by: default avatarSimon Horman <horms+renesas@verge.net.au>