Sebastian Sanchez authored
When the link is disabled and re-enabled, the host version bit is not set again, so the firmware behaves as though it’s interacting with an old driver. This causes LNI to get out of sync. The host version bit needs to be set at load_8051_firmware() and _dc_start(). Currently, it's only set at load_8051_firmware(). Create a common function to set the bit with the intent to make the code more maintainable in the future, set the host version bit at _dc_start() and modify the 8051 command API to prevent a deadlock as _dc_start() is already holding the dc8051 lock. Fixes: 913cc671 ("IB/hfi1: Always perform offline transition") Reviewed-by: Dennis Dalessandro <dennis.dalessandro@intel.com> Reviewed-by: Mike Marciniszyn <mike.marciniszyn@intel.com> Signed-off-by: Sebastian Sanchez <sebastian.sanchez@intel.com> Signed-off-by: Dennis Dalessandro <dennis.dalessandro@intel.com> Signed-off-by: Doug Ledford <dledford@redhat.com>
9be6a5d7