• Ard Biesheuvel's avatar
    s390: fix normalization bug in exception table sorting · bcb7825a
    Ard Biesheuvel authored
    The normalization pass in the sorting routine of the relative exception
    table serves two purposes:
    - it ensures that the address fields of the exception table entries are
      fully ordered, so that no ambiguities arise between entries with
      identical instruction offsets (i.e., when two instructions that are
      exactly 8 bytes apart each have an exception table entry associated with
      them)
    - it ensures that the offsets of both the instruction and the fixup fields
      of each entry are relative to their final location after sorting.
    
    Commit eb608fb3 ("s390/exceptions: switch to relative exception table
    entries") ported the relative exception table format from x86, but modified
    the sorting routine to only normalize the instruction offset field and not
    the fixup offset field. The result is that the fixup offset of each entry
    will be relative to the original location of the entry before sorting,
    likely leading to crashes when those entries are dereferenced.
    
    Fixes: eb608fb3 ("s390/exceptions: switch to relative exception table entries")
    Signed-off-by: default avatarArd Biesheuvel <ard.biesheuvel@linaro.org>
    Cc: <stable@vger.kernel.org>
    Signed-off-by: default avatarHeiko Carstens <heiko.carstens@de.ibm.com>
    Signed-off-by: default avatarMartin Schwidefsky <schwidefsky@de.ibm.com>
    bcb7825a
extable.c 2.17 KB