• Yangbo Lu's avatar
    ARM: dts: ls1021a: fix the value of TMR_FIPER1 · bdba5017
    Yangbo Lu authored
    The timer fixed interval period pulse generator register
    is used to generate periodic pulses. The down count
    register loads the value programmed in the fixed period
    interval (FIPER). At every tick of the timer accumulator
    overflow, the counter decrements by the value of
    TMR_CTRL[TCLK_PERIOD]. It generates a pulse when the down
    counter value reaches zero. It reloads the down counter
    in the cycle following a pulse. To use the TMR_FIPER1
    register to generate a 1 PPS event, the value
    (10^9 nanoseconds) - TCLK_PERIOD should be programmed.
    It should be 999999995 not 999999990 since TCLK_PERIOD
    is 5.
    Signed-off-by: default avatarYangbo Lu <yangbo.lu@nxp.com>
    Signed-off-by: default avatarShawn Guo <shawnguo@kernel.org>