Chen-Yu Tsai authored
The MMC controller can support DDR52 transfers under the new timing mode. According to the BSP kernel, the module clock has to be double the card clock, regardless of the bus width. The default timings in the hardware can be used. This also reworks the code setting the internal divider, getting rid of a extra conditional. Signed-off-by: Chen-Yu Tsai <wens@csie.org> Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com> Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>