V4L/DVB (8035): tda18271: dont touch EB14 if rf_cal lookup is out of range
The TDA18271HD/C1 rf_cal map lookup is expected to go out of range outside of the frequency window 41 MHz - 61.1 MHz. In these cases, the internal RF tracking filters calibration mechanism is used. Signed-off-by: Michael Krufky <mkrufky@linuxtv.org> Signed-off-by: Mauro Carvalho Chehab <mchehab@infradead.org>