powerpc/perf/hv-24x7: Fix passing of catalog version number
H_GET_24X7_CATALOG_PAGE needs to be passed the version number obtained from the first catalog page obtained previously. This is a 64 bit number, but create_events_from_catalog truncates it to 32-bit. This worked on POWER8, but POWER9 actually uses the upper bits so the call fails with H_P3 because the hypervisor doesn't recognize the version. This patch also adds the hcall return code to the error message, which is helpful when debugging the problem. Fixes: 5c5cd7b5 ("powerpc/perf/hv-24x7: parse catalog and populate sysfs with events") Reviewed-by: Sukadev Bhattiprolu <sukadev@linux.vnet.ibm.com> Signed-off-by: Thiago Jung Bauermann <bauerman@linux.vnet.ibm.com> Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>