hwmon: (emc1403) fix inverted store_hyst()
Attempts to set the hysteresis value to a temperature below the target limit fails with "write error: Numerical result out of range" due to an inverted comparison. Signed-off-by: Josef Gajdusek <atx@atx.name> Reviewed-by: Jean Delvare <jdelvare@suse.de> Cc: stable@vger.kernel.org [Guenter Roeck: Updated headline and description] Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Showing
Please register or sign in to comment