Commit 1810b3bb authored by Michael Hennerich's avatar Michael Hennerich Committed by Greg Kroah-Hartman

IIO: GYRO: ADXRS450: Don't exit probe, in case the power on default is not met.

If the part get's probed twice without hard reset in between, the power on default
register read-back can't be met. This shouldn't cause the second probe to fail.
So warn but don't exit.
Signed-off-by: default avatarMichael Hennerich <michael.hennerich@analog.com>
Acked-by: default avatarJonathan Cameron <jic23@cam.ac.uk>
Signed-off-by: default avatarGreg Kroah-Hartman <gregkh@suse.de>
parent 7dd04eb0
......@@ -278,11 +278,9 @@ static int adxrs450_initial_setup(struct adxrs450_state *st)
ret = adxrs450_spi_initial(st, &t, 1);
if (ret)
return ret;
if (t != 0x01) {
dev_err(&st->us->dev, "The initial response is not correct!\n");
return -ENODEV;
}
if (t != 0x01)
dev_warn(&st->us->dev, "The initial power on response "
"is not correct! Restart without reset?\n");
msleep(ADXRS450_STARTUP_DELAY);
ret = adxrs450_spi_initial(st, &t, 0);
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment