p54spi: Fix workqueue deadlock
priv->work must not be synced while priv->mutex is locked, because the mutex is taken in the work handler. Move cancel_work_sync down to after the device shutdown code. This is safe, because the work handler checks fw_state and bails out early in case of a race. Signed-off-by: Michael Buesch <m@bues.ch> Cc: <stable@vger.kernel.org> Acked-by: Christian Lamparter <chunkeey@googlemail.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>