Commit 484d578b authored by Viresh Kumar's avatar Viresh Kumar Committed by Tony Lindgren

ARM: dts: omap5: Add missing cooling device properties for CPUs

The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.

Add such missing properties.

Fix other missing properties (clocks, supply, clock latency) as well to
make it all work.
Signed-off-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: default avatarTony Lindgren <tony@atomide.com>
parent d6ace1c5
...@@ -61,6 +61,20 @@ cpu@1 { ...@@ -61,6 +61,20 @@ cpu@1 {
device_type = "cpu"; device_type = "cpu";
compatible = "arm,cortex-a15"; compatible = "arm,cortex-a15";
reg = <0x1>; reg = <0x1>;
operating-points = <
/* kHz uV */
1000000 1060000
1500000 1250000
>;
clocks = <&dpll_mpu_ck>;
clock-names = "cpu";
clock-latency = <300000>; /* From omap-cpufreq driver */
/* cooling options */
#cooling-cells = <2>; /* min followed by max */
}; };
}; };
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment