[PATCH] platform update for ES7000
This update only applies to Unisys' ES7000 server machines. The patch adds a OEM id check to verify the current machine running is actually a Unisys type box before executing the Unisys OEM parser routine. It also increases the MAX_MP_BUSSES definition from 32 to 256. On the ES7000s, bus ID numbering can range from 0 to 255. Without the patch, the system panics if booted with acpi=off. This patch has been tested and verified on an authentic ES7000 machine. Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>