Commit 818f3331 authored by Bruce Allan's avatar Bruce Allan Committed by David S. Miller

e1000e: do not initiate autonegotiation during OEM configuration

When configuring the OEM bits in the PHY on 82577/82578, do not restart
autonegotiation if the firmware is blocking it (e.g. when an IDE-R session
is active) because the link must not go down.
Signed-off-by: default avatarBruce Allan <bruce.w.allan@intel.com>
Signed-off-by: default avatarJeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 189983d4
......@@ -1118,7 +1118,8 @@ static s32 e1000_oem_bits_config_ich8lan(struct e1000_hw *hw, bool d0_state)
oem_reg |= HV_OEM_BITS_LPLU;
}
/* Restart auto-neg to activate the bits */
oem_reg |= HV_OEM_BITS_RESTART_AN;
if (!e1000_check_reset_block(hw))
oem_reg |= HV_OEM_BITS_RESTART_AN;
ret_val = hw->phy.ops.write_phy_reg_locked(hw, HV_OEM_BITS, oem_reg);
out:
......