clocksource: samsung_pwm_timer: Work around rounding errors in clockevents core
Due to rounding errors in clockevents core (in conversions between ticks and nsecs), it might happen that the set_next_event callback gets called with cycles = 0, causing the code to incorrectly program the PWM timer. This patch modifies the callback to program the timer for 1 tick, if received tick count value is 0. Signed-off-by:Tomasz Figa <t.figa@samsung.com> Signed-off-by:
Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by:
Arnd Bergmann <arnd@arndb.de> Acked-by:
Kukjin Kim <kgene.kim@samsung.com> Signed-off-by:
Olof Johansson <olof@lixom.net>