Commit 8f7e5798 authored by Andres Salomon's avatar Andres Salomon Committed by Anton Vorontsov

olpc_battery: Ensure that the TRICKLE bit is checked

There are times when the battery is present but trickle charging,
and the EC sets only the TRICKLE bit. So we must check for the bit
when we're checking the charging/present status.
Signed-off-by: default avatarAndres Salomon <dilinger@collabora.co.uk>
Signed-off-by: default avatarAnton Vorontsov <cbouatmailru@gmail.com>
parent 04a820ea
......@@ -36,6 +36,7 @@
#define BAT_STAT_AC 0x10
#define BAT_STAT_CHARGING 0x20
#define BAT_STAT_DISCHARGING 0x40
#define BAT_STAT_TRICKLE 0x80
#define BAT_ERR_INFOFAIL 0x02
#define BAT_ERR_OVERVOLTAGE 0x04
......@@ -90,7 +91,7 @@ static char bat_serial[17]; /* Ick */
static int olpc_bat_get_status(union power_supply_propval *val, uint8_t ec_byte)
{
if (olpc_platform_info.ecver > 0x44) {
if (ec_byte & BAT_STAT_CHARGING)
if (ec_byte & (BAT_STAT_CHARGING | BAT_STAT_TRICKLE))
val->intval = POWER_SUPPLY_STATUS_CHARGING;
else if (ec_byte & BAT_STAT_DISCHARGING)
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
......@@ -220,7 +221,8 @@ static int olpc_bat_get_property(struct power_supply *psy,
It doesn't matter though -- the EC will return the last-known
information, and it's as if we just ran that _little_ bit faster
and managed to read it out before the battery went away. */
if (!(ec_byte & BAT_STAT_PRESENT) && psp != POWER_SUPPLY_PROP_PRESENT)
if (!(ec_byte & (BAT_STAT_PRESENT | BAT_STAT_TRICKLE)) &&
psp != POWER_SUPPLY_PROP_PRESENT)
return -ENODEV;
switch (psp) {
......@@ -230,7 +232,8 @@ static int olpc_bat_get_property(struct power_supply *psy,
return ret;
break;
case POWER_SUPPLY_PROP_PRESENT:
val->intval = !!(ec_byte & BAT_STAT_PRESENT);
val->intval = !!(ec_byte & (BAT_STAT_PRESENT |
BAT_STAT_TRICKLE));
break;
case POWER_SUPPLY_PROP_HEALTH:
......